Lightning Protection Systems & Components
Complete protection against lightning strikes with our comprehensive range of products and solutions designed for maximum safety and reliability.
Lightning Arresters
Our lightning arresters provide the first line of defense against direct strikes and voltage surges:
- Class I, II & III arresters for different protection levels
- Spark gap and valve-type technologies
- Polymer-housed and porcelain-housed variants
- For voltages ranging from 230V to 400kV
a) Earthing Electrodes
Essential components for safe dissipation of lightning currents into the ground:
- Copper Bonded Rods: 14mm-25mm diameter, 1.2m-3m lengths
- Galvanized Iron Rods: Cost-effective grounding solution
- Solid Copper Rods: Premium corrosion-resistant electrodes
- Chemical Electrodes: For high-resistance soil conditions
- Strip Electrodes: 25x3mm to 50x6mm copper strips
b) Earthing Compound
Special compounds to enhance grounding system performance:
- Bentonite-Based: Natural clay compound with high water retention
- Conductive Concrete: For urban areas with limited space
- Carbon-Based: Low-resistance backfill material
- Marconite: Highly conductive sintered material (0.002 ohm-m)
- Reduces soil resistivity by up to 80%
c) Earthpit Chamber
Protective enclosures for grounding system access points:
- Material Types: PVC, FRP, or cast iron construction
- Sizes: 300x300mm to 600x600mm
- Waterproof and corrosion-resistant designs
- Lockable versions for security
- Color options: Red, yellow, or black
d) Lightning Protection System
Conventional (Franklin Rod) System
- Air terminals (lightning rods) in 2m, 3m, and 4m heights
- Stainless steel (304/316) or copper conductors
- Rolling sphere method protection design
- Mesh conductor network for flat roofs
- Down conductors with 100mm² cross-section
ESE (Early Streamer Emission) System
- Advanced ionization technology for larger protection radius
- Protection radius up to 107m (Class I, ΔT=60μs)
- Stainless steel (316L) construction
- NF C 17-102 certified models
- Withstand current: 100kA (10/350μs)
System Advantages
- Complete protection as per IEC 62305 standards
- Custom-designed for each facility
- 25+ year lifespan for main components
- Low maintenance requirements
- Compatible with all building types
- Professional installation support
Typical Applications
Buildings
- High-rise apartments
- Commercial complexes
- Industrial plants
Infrastructure
- Telecom towers
- Power substations
- Airports
Special Structures
- Historical monuments
- Wind turbines
- Oil & gas facilities